电针频率对大鼠脊髓灌流液中SOM和CGRP含量的影响
摘要
采用放射免疫测定法,分析不同频率电针刺激下大鼠脊髓灌流液中生长抑制素(SOM)和降钙素基因相关肽(CGRP)放免活性(ir)的变化。电针频率选择2,15和100Hz。分别收集电针前、中、后各30min脊髓灌流液进行测定。实验结果如下:(1)低频(2Hz)电针使脊髓灌流液中SOM-ir水平升高39%( P<0.05),CGRP-ir降低47%( P<0.05);(2)中频电针(15Hz)则相反,使SOM-ir水平下降37%( P<0.05),CGRP-ir水平增高92%( P<0.05);(3)高频电针(100Hz)使SOM-ir水平减少30%( P<0.01),但不影响CGRP-ir的水平。
关键词: 生长抑素放免活性(SOM-ir); 降钙素基因相关肽放免活性(CGRP-ir); 电针; 放射免疫分析; 脊髓; 释放
Frequency dependence o f somatostatin and calcitonin gene related peptide release induced by electroacupuncture in rat spinal cord
Abstract
Key words: Immunoreactivity of somatostatin(SOM-ir);Immunoreactivity of calcitonin gene-related peptide(CGRP-ir);Electroacupuncture;Radioimmunoassay;Spinal;Cord release
收稿日期: 录用日期:
通讯作者: E-mail:
引用本文:
. 电针频率对大鼠脊髓灌流液中SOM和CGRP含量的影响[J]. 生理学报 1998; 50 (1): .